Noritz 90
Noritz error code 90: combustion abnormality
Short answer
Code 90 indicates a combustion abnormality caused by an improper mix of air and fuel. Noritz lists insufficient gas supply, a blockage in the vent and debris in the fan motor or unit as causes. Code 10 is often an early warning before code 90.
Code 90 is a combustion code. The heater detected that the mixture of air and gas was not right after repeated attempts, and it shut down.
Noritz notes that code 10, also a combustion abnormality, is usually a precursor to the more severe code 90.
If you smell gas, do not relight or reset anything and do not touch electrical switches. Leave the building and call your gas utility from outside.
Common causes
- Insufficient gas pressure. An undersized line or a supply problem.
- Venting blockage. An obstructed intake or exhaust, or a vent that is too long.
- A dirty unit. Dust and lint inside the heater restrict combustion air. Noritz technicians clean units with compressed air.
What to do
Check the vent terminals for obvious blockages, then call a licensed contractor. The fix involves measuring gas pressure with a digital manometer, checking vent length and settings, and cleaning the inside of the unit.
Common questions
Can I reset Noritz code 90 myself?
Some models require a specific reset procedure after code 90. More importantly, the combustion problem needs to be diagnosed by a licensed contractor.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Noritz codes
| Code | Meaning |
|---|---|
| 10 | Combustion abnormality (warning) |
| 11 | Ignition failure |
| 12 | Flame loss |
| 13 | Optional CO alarm device fault |
| 14 | Thermal fuse blown (severe overheat) |
| 16 | Outlet water temperature spiked too high |
| 20 | High limit switch tripped |
| 29 | Condensate drain problem (condensing models) |
| 67 | Air gas mixer (AGM) abnormality |
| 71 | Gas valve circuit abnormality |
| 90 | Combustion abnormality |
| 92 | Neutralizer near end of life (first warning) |
| 93 | Neutralizer at end of life |