Navien E016

Navien E016: heat exchanger overheat, causes and fixes

Short answer

E016 means the Navien shut down because the heat exchanger overheated. The most common causes are scale buildup inside the heat exchanger and restricted water flow, often from a clogged cold water inlet filter.

In this guide
  1. What to check first
  2. Common causes
  3. When to call a technician

Navien lists E016 as heat exchanger overheat. The unit shuts off the burner to protect itself when the water or metal inside gets hotter than it should.

Overheating almost always comes back to one thing: heat is not moving into the water fast enough. That usually means scale or low flow.

What to check first

  1. Think about when the unit was last descaled. If it has been more than a year, or you have hard water, scale is the prime suspect.
  2. Clean the cold water inlet filter. Close the cold water valve, relieve pressure at a hot tap, then remove and rinse the filter as shown in your manual.
  3. Make sure the cold and hot isolation valves under the unit are fully open.
  4. Turn the unit off with the power button, wait a few minutes, turn it back on and run hot water.

Common causes

Scale in the heat exchanger

Mineral scale coats the inside of the heat exchanger and acts as insulation. The fix is to descale a tankless water heater with a pump kit and vinegar or an approved descaler.

Low or interrupted water flow

A clogged inlet filter, a partly closed valve or a recirculation problem can reduce flow through the heat exchanger so the water overheats.

Sensor or control faults

If flow and scale are ruled out, a technician will check the temperature sensors, the high limit switch and the control board.

When to call a technician

Call a licensed installer if E016 returns after you have descaled the unit and cleaned the inlet filter. Stop resetting it at that point: repeated overheating can damage the heat exchanger.

Common questions

Can I reset Navien E016 myself?

You can power cycle the unit, but if scale or low flow caused the overheat, E016 will return until that is fixed.

How often should I descale my Navien to prevent E016?

Once a year for most homes, and more often with hard water.

Was this article helpful?

Other Navien codes

CodeMeaning
E003 Ignition failure
E004 False flame detection
E012 Flame loss
E016 Heat exchanger overheat
E030 Abnormal exhaust temperature
E031 Burner overheating
E046 Limit control (high limit switch) abnormal
E047 Exhaust temperature sensor (thermistor) open or short
E060 Dual venturi abnormal operation
E109 Fan motor abnormal operation
E110 Exhaust blockage (condensate blockage)
E407 Hot water outlet temperature sensor open or short
E421 Cold water inlet temperature sensor open or short
E432 Cold water inlet 2 sensor open or short
E434 Water adjustment valve fault
E438 Circulation pump fault
E439 Flow sensor fault
E441 Second hot water temperature sensor open or short
E445 Bypass mixing valve fault
E515 Control board (PCB) abnormal operation
E517 DIP switch setting fault
E593 Front panel key fault
E594 EEPROM (memory) fault
E615 Input and memory fault
E736 Cascade communication fault
E740 Outdoor temperature sensor fault
E760 Flushing or service alarm
E762 Vent pipe not properly inserted
E773 Using the wrong gas
E782 Main panel communication fault
E785 Flow switch or flow sensor fault (with AHU)
E788 Gas type mismatch between board DIP switch and front panel

All Navien error codes