Navien water heater error codes
How to read the codes
Navien tankless water heaters and combi boilers show an E code, such as E003, on the front panel when they shut down. Find your code in the table below, then open the full guide where one is linked.
All Navien codes
| Code | Meaning |
|---|---|
| E003 | Ignition failure Full guide |
| E004 | False flame detection Full guide |
| E012 | Flame loss Full guide |
| E016 | Heat exchanger overheat Full guide |
| E030 | Abnormal exhaust temperature Full guide |
| E031 | Burner overheating Full guide |
| E046 | Limit control (high limit switch) abnormal Full guide |
| E047 | Exhaust temperature sensor (thermistor) open or short Full guide |
| E060 | Dual venturi abnormal operation Full guide |
| E109 | Fan motor abnormal operation Full guide |
| E110 | Exhaust blockage (condensate blockage) Full guide |
| E127 | Air pressure sensor fault |
| E407 | Hot water outlet temperature sensor open or short Full guide |
| E421 | Cold water inlet temperature sensor open or short Full guide |
| E432 | Cold water inlet 2 sensor open or short Full guide |
| E434 | Water adjustment valve fault Full guide |
| E438 | Circulation pump fault Full guide |
| E439 | Flow sensor fault Full guide |
| E441 | Second hot water temperature sensor open or short Full guide |
| E445 | Bypass mixing valve fault Full guide |
| E515 | Control board (PCB) abnormal operation Full guide |
| E517 | DIP switch setting fault Full guide |
| E593 | Front panel key fault Full guide |
| E594 | EEPROM (memory) fault Full guide |
| E615 | Input and memory fault Full guide |
| E736 | Cascade communication fault Full guide |
| E740 | Outdoor temperature sensor fault Full guide |
| E760 | Flushing or service alarm Full guide |
| E762 | Vent pipe not properly inserted Full guide |
| E773 | Using the wrong gas Full guide |
| E782 | Main panel communication fault Full guide |
| E785 | Flow switch or flow sensor fault (with AHU) Full guide |
| E788 | Gas type mismatch between board DIP switch and front panel Full guide |
Navien codes fall into a few groups. Codes near the start of the list, like E003, E012 and E016, relate to combustion and heat. Codes in the 400s point to a sensor, valve or pump. Codes in the 500s and above generally point to the control board.
Many combustion codes share the same basic causes: gas supply, venting and the condensate drain. Those are also the things a homeowner can check without opening the unit.
If you smell gas, do not reset the unit or touch any switches. Leave the building and call your gas utility from outside.
How to reset a Navien error code
- Turn off all hot water taps.
- Press the power button on the front panel to turn the unit off, wait about a minute, then turn it back on.
- Open a hot water tap and watch whether the unit fires normally.
If the same code returns, the cause is still present. Repeated resets on a combustion or overheating code are not a repair.
The codes homeowners see most
Ignition and flame: E003 and E012
E003 means the burner did not light. E012 means it lit and lost the flame. Check the gas valve, other gas appliances, the propane level and the vents.
Overheating: E016 and E030
E016 means the heat exchanger got too hot, and E030 means the exhaust temperature was abnormal. Scale buildup and a clogged inlet water filter are frequent causes, so maintenance history matters.
Exhaust or condensate blockage: E110
E110 means the exhaust path is blocked, and on condensing units that includes a condensate drain that cannot drain. Check the vent outside and the condensate line.
What you can safely check yourself
- The gas valve to the heater, and whether other gas appliances work.
- Intake and exhaust vent terminals outside, for snow, ice, debris or nests.
- The condensate drain line, for kinks, clogs or ice.
- The cold water inlet filter, which can clog with sediment.
- When the unit was last descaled.
When to call a technician
Sensor, valve, fan and control board codes, and any combustion code that returns after the checks above, need a licensed installer with the right test equipment. Navien's service steps for these codes involve the sealed combustion area and gas pressure testing.
Common questions
Why does my Navien keep showing the same error code?
A code that returns after a reset means the underlying cause has not been fixed. Note when it happens, such as only in cold weather or when other gas appliances run, and share that with your technician.
Do Navien combi boilers use the same codes?
Many Navien codes are shared across tankless water heaters and combi boilers, but some codes only apply to certain models. Check the manual for your model.