Navien E407
Navien E407: hot water outlet sensor fault
Short answer
E407 means the hot water outlet thermistor, the sensor that measures the temperature of the water leaving the heater, is reading as an open or short circuit. The wiring and connectors are checked first, and the sensor is replaced if it has failed.
In this guide
A tankless heater adjusts its flame based on how hot the water leaving it is. The hot water outlet thermistor provides that reading. E407 means the reading is electrically invalid, so the heater cannot control the temperature safely and stops.
The meaning below comes from Navien's manuals for its NPE condensing tankless water heaters. Many codes are shared with Navien combi boilers, but check the manual for your model if something does not match.
For this code, Navien's user manual directs owners to contact Navien technical support (1-800-519-8794) or a licensed installer.
Common causes
- A loose or corroded connector at the sensor
- A damaged wire between the sensor and the control board
- A sensor that has failed, sometimes after scale or water exposure
The repair
A technician checks the connector and wiring, then measures the sensor. If it reads open or shorted, it is replaced. The part is inexpensive; the work involves shutting off the water and working inside the cabinet.
How to reset a Navien
- Close all hot water taps.
- Press the power button on the front panel to turn the unit off, wait about a minute, then turn it back on.
- Open a hot tap and watch whether the code returns.
If E407 returns right away, the sensor or wiring still has a fault.
See every code on our Navien error codes page.
Common questions
Can I use hot water with Navien E407?
No. Without a valid outlet temperature reading, the heater will not run normally.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Navien codes
| Code | Meaning |
|---|---|
| E003 | Ignition failure |
| E004 | False flame detection |
| E012 | Flame loss |
| E016 | Heat exchanger overheat |
| E030 | Abnormal exhaust temperature |
| E031 | Burner overheating |
| E046 | Limit control (high limit switch) abnormal |
| E047 | Exhaust temperature sensor (thermistor) open or short |
| E060 | Dual venturi abnormal operation |
| E109 | Fan motor abnormal operation |
| E110 | Exhaust blockage (condensate blockage) |
| E407 | Hot water outlet temperature sensor open or short |
| E421 | Cold water inlet temperature sensor open or short |
| E432 | Cold water inlet 2 sensor open or short |
| E434 | Water adjustment valve fault |
| E438 | Circulation pump fault |
| E439 | Flow sensor fault |
| E441 | Second hot water temperature sensor open or short |
| E445 | Bypass mixing valve fault |
| E515 | Control board (PCB) abnormal operation |
| E517 | DIP switch setting fault |
| E593 | Front panel key fault |
| E594 | EEPROM (memory) fault |
| E615 | Input and memory fault |
| E736 | Cascade communication fault |
| E740 | Outdoor temperature sensor fault |
| E760 | Flushing or service alarm |
| E762 | Vent pipe not properly inserted |
| E773 | Using the wrong gas |
| E782 | Main panel communication fault |
| E785 | Flow switch or flow sensor fault (with AHU) |
| E788 | Gas type mismatch between board DIP switch and front panel |