Navien E441

Navien E441: hot water sensor 2 fault

Short answer

E441 means a second hot water temperature sensor in a Navien heater is reading as an open or short circuit. Navien's NPE-A manual labels it hot water inlet 2, and other manuals call it hot water outlet 2. A technician checks the connector and wiring and replaces the sensor if it has failed.

In this guide
  1. A note on the name
  2. Common causes
  3. The repair
  4. How to reset a Navien
  5. Before you call

Navien heaters use several temperature sensors to control the burner and mix water to your set temperature. E441 is a fault in one of the hot water sensors, which the manuals call sensor 2.

The meaning below comes from Navien's manuals for its NPE condensing tankless water heaters. Navien directs owners to its technical support line (1-800-519-8794) or a licensed installer for this code.

A note on the name

Navien's NPE-A user manual describes E441 as hot water inlet 2, while other Navien manuals list it as hot water outlet 2. Either way, it is a hot water temperature sensor with an electrical fault, and the repair is the same.

Common causes

  • A loose, wet or corroded connector
  • Damaged wiring to the control board
  • A failed sensor

The repair

After checking the wiring, a technician measures the sensor and replaces it if it reads open or shorted. The part is inexpensive.

How to reset a Navien

  1. Close all hot water taps.
  2. Turn the unit off with the power button on the front panel, wait about a minute, then turn it back on.
  3. Open a hot tap and watch whether the code returns.

Before you call

Have the model and serial number from the rating label ready, along with the exact code and when it appears: at startup, during use, or only at high demand. Mention any recent work on the gas, water or electrical supply and when the heater was last descaled. This helps the technician bring the right parts and often saves a second visit.

See every code on our Navien error codes page.

Common questions

Is Navien E441 the same as E407?

They are similar. E407 is the main hot water outlet sensor; E441 is a second hot water sensor.

Was this article helpful?

Other Navien codes

CodeMeaning
E003 Ignition failure
E004 False flame detection
E012 Flame loss
E016 Heat exchanger overheat
E030 Abnormal exhaust temperature
E031 Burner overheating
E046 Limit control (high limit switch) abnormal
E047 Exhaust temperature sensor (thermistor) open or short
E060 Dual venturi abnormal operation
E109 Fan motor abnormal operation
E110 Exhaust blockage (condensate blockage)
E407 Hot water outlet temperature sensor open or short
E421 Cold water inlet temperature sensor open or short
E432 Cold water inlet 2 sensor open or short
E434 Water adjustment valve fault
E438 Circulation pump fault
E439 Flow sensor fault
E441 Second hot water temperature sensor open or short
E445 Bypass mixing valve fault
E515 Control board (PCB) abnormal operation
E517 DIP switch setting fault
E593 Front panel key fault
E594 EEPROM (memory) fault
E615 Input and memory fault
E736 Cascade communication fault
E740 Outdoor temperature sensor fault
E760 Flushing or service alarm
E762 Vent pipe not properly inserted
E773 Using the wrong gas
E782 Main panel communication fault
E785 Flow switch or flow sensor fault (with AHU)
E788 Gas type mismatch between board DIP switch and front panel

All Navien error codes