Navien E740
Navien E740: outdoor temperature sensor fault
Short answer
Navien E740 is an outdoor temperature sensor fault. Navien notes it applies when an air handler unit (AHU) for space heating is connected, since the outdoor sensor helps control heating. Damaged or disconnected sensor wiring or a failed sensor are the usual causes. Navien's manual says to contact technical support.
In combination systems, where the Navien heats both water and the home through an air handler, an outdoor sensor tells the system how cold it is outside. E740 means that sensor reading is invalid.
The meaning and recommended action below come from Navien's User's Information Manual for NPE-2 condensing water heaters (NPE-180A2, NPE-210A2, NPE-240A2 and the S2 models). Navien technical support: 1-800-519-8794.
Navien notes this code applies when an air handler unit (AHU) for space heating is connected to the water heater, a setup used in combination water and space heating systems.
What to check
- Look at the outdoor sensor, usually on a north-facing exterior wall, for damage.
- Check that its wire has not been cut or pulled loose, for example by landscaping or siding work.
What a technician does
Tests the sensor and its wiring, and replaces the sensor if it has failed. Hot water heating itself is usually unaffected, but space heating control is.
How to reset it
Navien says you can try resetting the water heater by pressing the Back button on the front panel. If the code returns, the cause is still there and the unit needs service.
Before you call
Have the model number and serial number from the rating plate on the side of the unit ready, along with the date it was installed and the exact code. Navien asks for this information when you contact technical support, and your installer should be your first call for warranty service.
See every code on our Navien error codes page.
Common questions
Does Navien E740 stop hot water?
It relates to the outdoor sensor used for space heating with an air handler. A technician can confirm how your system responds.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Navien codes
| Code | Meaning |
|---|---|
| E003 | Ignition failure |
| E004 | False flame detection |
| E012 | Flame loss |
| E016 | Heat exchanger overheat |
| E030 | Abnormal exhaust temperature |
| E031 | Burner overheating |
| E046 | Limit control (high limit switch) abnormal |
| E047 | Exhaust temperature sensor (thermistor) open or short |
| E060 | Dual venturi abnormal operation |
| E109 | Fan motor abnormal operation |
| E110 | Exhaust blockage (condensate blockage) |
| E407 | Hot water outlet temperature sensor open or short |
| E421 | Cold water inlet temperature sensor open or short |
| E432 | Cold water inlet 2 sensor open or short |
| E434 | Water adjustment valve fault |
| E438 | Circulation pump fault |
| E439 | Flow sensor fault |
| E441 | Second hot water temperature sensor open or short |
| E445 | Bypass mixing valve fault |
| E515 | Control board (PCB) abnormal operation |
| E517 | DIP switch setting fault |
| E593 | Front panel key fault |
| E594 | EEPROM (memory) fault |
| E615 | Input and memory fault |
| E736 | Cascade communication fault |
| E740 | Outdoor temperature sensor fault |
| E760 | Flushing or service alarm |
| E762 | Vent pipe not properly inserted |
| E773 | Using the wrong gas |
| E782 | Main panel communication fault |
| E785 | Flow switch or flow sensor fault (with AHU) |
| E788 | Gas type mismatch between board DIP switch and front panel |