Navien E740: outdoor temperature sensor fault

Short answer

Navien E740 is an outdoor temperature sensor fault. Navien notes it applies when an air handler unit (AHU) for space heating is connected, since the outdoor sensor helps control heating. Damaged or disconnected sensor wiring or a failed sensor are the usual causes. Navien's manual says to contact technical support.

In this guide
  1. What to check
  2. What a technician does
  3. How to reset it
  4. Before you call

In combination systems, where the Navien heats both water and the home through an air handler, an outdoor sensor tells the system how cold it is outside. E740 means that sensor reading is invalid.

The meaning and recommended action below come from Navien's User's Information Manual for NPE-2 condensing water heaters (NPE-180A2, NPE-210A2, NPE-240A2 and the S2 models). Navien technical support: 1-800-519-8794.

Navien notes this code applies when an air handler unit (AHU) for space heating is connected to the water heater, a setup used in combination water and space heating systems.

What to check

  • Look at the outdoor sensor, usually on a north-facing exterior wall, for damage.
  • Check that its wire has not been cut or pulled loose, for example by landscaping or siding work.

What a technician does

Tests the sensor and its wiring, and replaces the sensor if it has failed. Hot water heating itself is usually unaffected, but space heating control is.

How to reset it

Navien says you can try resetting the water heater by pressing the Back button on the front panel. If the code returns, the cause is still there and the unit needs service.

Before you call

Have the model number and serial number from the rating plate on the side of the unit ready, along with the date it was installed and the exact code. Navien asks for this information when you contact technical support, and your installer should be your first call for warranty service.

See every code on our Navien error codes page.

Common questions

Does Navien E740 stop hot water?

It relates to the outdoor sensor used for space heating with an air handler. A technician can confirm how your system responds.

Was this article helpful?

Other Navien codes

CodeMeaning
E003 Ignition failure
E004 False flame detection
E012 Flame loss
E016 Heat exchanger overheat
E030 Abnormal exhaust temperature
E031 Burner overheating
E046 Limit control (high limit switch) abnormal
E047 Exhaust temperature sensor (thermistor) open or short
E060 Dual venturi abnormal operation
E109 Fan motor abnormal operation
E110 Exhaust blockage (condensate blockage)
E407 Hot water outlet temperature sensor open or short
E421 Cold water inlet temperature sensor open or short
E432 Cold water inlet 2 sensor open or short
E434 Water adjustment valve fault
E438 Circulation pump fault
E439 Flow sensor fault
E441 Second hot water temperature sensor open or short
E445 Bypass mixing valve fault
E515 Control board (PCB) abnormal operation
E517 DIP switch setting fault
E593 Front panel key fault
E594 EEPROM (memory) fault
E615 Input and memory fault
E736 Cascade communication fault
E740 Outdoor temperature sensor fault
E760 Flushing or service alarm
E762 Vent pipe not properly inserted
E773 Using the wrong gas
E782 Main panel communication fault
E785 Flow switch or flow sensor fault (with AHU)
E788 Gas type mismatch between board DIP switch and front panel

All Navien error codes