Navien E445
Navien E445: mixing valve fault
Short answer
E445 means abnormal operation of the bypass mixing valve, which blends some cold water into the hot so the outlet temperature stays steady. Navien directs owners to technical support or a licensed installer. The usual repair is checking the valve wiring and replacing the valve.
Navien heaters use a mixing valve to blend cold water into the heated water. This helps prevent temperature spikes and keeps the outlet steady. E445 means the valve is not responding the way the control board expects.
The meaning below comes from Navien's manuals for its NPE condensing tankless water heaters. Navien directs owners to its technical support line (1-800-519-8794) or a licensed installer for this code.
What you might notice
- Hot water that swings between too hot and lukewarm
- The heater shutting down with E445 during use
Common causes
- A failed valve motor
- Loose or damaged wiring
- Scale or debris affecting the valve in hard water areas
What you can do
Reset the unit once. If E445 returns, schedule service. Keeping up with flushing and cleaning the inlet filter reduces the chance of scale affecting valves.
How to reset a Navien
- Close all hot water taps.
- Turn the unit off with the power button on the front panel, wait about a minute, then turn it back on.
- Open a hot tap and watch whether the code returns.
Before you call
Have the model and serial number from the rating label ready, along with the exact code and when it appears: at startup, during use, or only at high demand. Mention any recent work on the gas, water or electrical supply and when the heater was last descaled. This helps the technician bring the right parts and often saves a second visit.
See every code on our Navien error codes page.
Common questions
Can I bypass the mixing valve on a Navien?
No. It helps protect against scalding temperature swings and should be repaired, not bypassed.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Navien codes
| Code | Meaning |
|---|---|
| E003 | Ignition failure |
| E004 | False flame detection |
| E012 | Flame loss |
| E016 | Heat exchanger overheat |
| E030 | Abnormal exhaust temperature |
| E031 | Burner overheating |
| E046 | Limit control (high limit switch) abnormal |
| E047 | Exhaust temperature sensor (thermistor) open or short |
| E060 | Dual venturi abnormal operation |
| E109 | Fan motor abnormal operation |
| E110 | Exhaust blockage (condensate blockage) |
| E407 | Hot water outlet temperature sensor open or short |
| E421 | Cold water inlet temperature sensor open or short |
| E432 | Cold water inlet 2 sensor open or short |
| E434 | Water adjustment valve fault |
| E438 | Circulation pump fault |
| E439 | Flow sensor fault |
| E441 | Second hot water temperature sensor open or short |
| E445 | Bypass mixing valve fault |
| E515 | Control board (PCB) abnormal operation |
| E517 | DIP switch setting fault |
| E593 | Front panel key fault |
| E594 | EEPROM (memory) fault |
| E615 | Input and memory fault |
| E736 | Cascade communication fault |
| E740 | Outdoor temperature sensor fault |
| E760 | Flushing or service alarm |
| E762 | Vent pipe not properly inserted |
| E773 | Using the wrong gas |
| E782 | Main panel communication fault |
| E785 | Flow switch or flow sensor fault (with AHU) |
| E788 | Gas type mismatch between board DIP switch and front panel |