Navien E110: exhaust or condensate blockage, causes and fixes

Short answer

E110 means the Navien detected an exhaust blockage, which Navien also lists as a condensate blockage. Check the outside vent terminals for obstructions and make sure the condensate drain line is not clogged, kinked or frozen.

In this guide
  1. What to check first
  2. Winter and E110
  3. When to call a technician

Navien defines E110 as an exhaust blockage, with condensate blockage named as a cause. On a condensing heater, the exhaust and the condensate drain are connected: if condensate cannot drain, it backs up into the exhaust path.

That means E110 is often something you can find yourself.

If you smell gas, do not reset the unit or touch any switches. Leave the building and call your gas utility from outside.

What to check first

  1. Go outside and check the exhaust and intake terminals for snow, ice, leaves, nests or anything placed against them.
  2. Follow the condensate drain line from the unit to where it drains. Look for kinks, sags that hold water, clogs or ice.
  3. If there is a condensate neutralizer, make sure it is not full of debris.
  4. Turn the unit off with the power button, wait a minute and turn it back on.

Winter and E110

Condensate lines that run through a cold garage, crawl space or outside wall can freeze. Once the ice melts the code may clear, but it will return in the next cold snap unless the line is rerouted or protected.

When to call a technician

If the vents and drain are clear and E110 returns, a technician should check the vent installation, the condensate trap inside the unit and the sensors. Do not run the heater with a known exhaust problem. Keep a working carbon monoxide detector in the home.

Common questions

Can a frozen drain line cause Navien E110?

Yes. A frozen condensate line backs water up into the exhaust path, which is one of the most common winter causes of E110.

Should I keep resetting Navien E110?

No. Clear the vent terminals and the condensate line first. If the code returns, have the unit inspected, because it involves the exhaust system.

Was this article helpful?

Other Navien codes

CodeMeaning
E003 Ignition failure
E004 False flame detection
E012 Flame loss
E016 Heat exchanger overheat
E030 Abnormal exhaust temperature
E031 Burner overheating
E046 Limit control (high limit switch) abnormal
E047 Exhaust temperature sensor (thermistor) open or short
E060 Dual venturi abnormal operation
E109 Fan motor abnormal operation
E110 Exhaust blockage (condensate blockage)
E407 Hot water outlet temperature sensor open or short
E421 Cold water inlet temperature sensor open or short
E432 Cold water inlet 2 sensor open or short
E434 Water adjustment valve fault
E438 Circulation pump fault
E439 Flow sensor fault
E441 Second hot water temperature sensor open or short
E445 Bypass mixing valve fault
E515 Control board (PCB) abnormal operation
E517 DIP switch setting fault
E593 Front panel key fault
E594 EEPROM (memory) fault
E615 Input and memory fault
E736 Cascade communication fault
E740 Outdoor temperature sensor fault
E760 Flushing or service alarm
E762 Vent pipe not properly inserted
E773 Using the wrong gas
E782 Main panel communication fault
E785 Flow switch or flow sensor fault (with AHU)
E788 Gas type mismatch between board DIP switch and front panel