Rinnai 03

Rinnai code 03: power interruption during bath fill

Short answer

Code 03 means the power was interrupted while the heater was filling a bathtub with its bath fill feature. Rinnai's steps are to turn off all hot water fixtures and press the ON/OFF button on the controller twice. If the code comes back after three resets, Rinnai says to replace the control board.

In this guide
  1. How to clear it
  2. If it keeps coming back
  3. Protecting the unit from power problems
  4. Before you call

Some Rinnai systems include a bath fill controller that fills the tub to a set level and temperature. Code 03 tells you the power dropped while that was happening, so the heater stopped the fill for safety.

The meaning and service steps below come from Rinnai's own diagnostic code guide for its tankless water heaters.

How to clear it

  1. Turn off all hot water fixtures.
  2. Press the ON/OFF button on the controller twice. This resets the code.
  3. Check the tub level before using bath fill again.

If it keeps coming back

A single code 03 after a storm or a tripped breaker is normal. Rinnai's guide says that if the code reappears after the heater has been reset three times, the control board should be replaced. At that point, have a technician confirm the power supply to the unit is stable before a new board goes in.

Protecting the unit from power problems

  • Plug the heater into a properly grounded outlet on a dedicated circuit where possible.
  • Consider a surge protector rated for appliances.
  • Have an electrician look at breakers that trip often.

Before you call

Have the model and serial number from the rating label ready, along with the exact code and when it appears: at startup, during use, or only at high demand. Mention any recent work on the gas, water or electrical supply and when the heater was last descaled. This helps the technician bring the right parts and often saves a second visit.

See every code on our Rinnai error codes page.

Common questions

Is Rinnai code 03 serious?

Usually not. It is often a one-time code after a power blip. It only points to a control board problem if it keeps returning.

Was this article helpful?

Other Rinnai codes

CodeMeaning
02 No burner operation during freeze protection
03 Power interruption during bath fill
05 Bypass flow control device fault
10 Air supply, exhaust blockage or condensate trap full
11 No ignition
12 Flame failure
14 Thermal fuse or overheat sensor tripped
15 Venturi control fault
16 Outgoing water temperature too high (safety shutdown)
17 Venturi blockage
19 Electrical grounding fault
21 Data transfer error after a control board replacement
25 Condensate drain clogged or condensate pump error
32 Outgoing water temperature sensor (thermistor) fault
33 Heat exchanger temperature sensor (thermistor) fault
34 Combustion air temperature sensor fault
38 Exhaust gas temperature sensor fault
41 Freeze protection sensor fault
51 Inlet water temperature sensor fault
52 Gas valve or modulating solenoid valve signal fault
54 High exhaust gas temperature
57 Burner overheat switch open
58 Secondary heat exchanger overheat
61 Combustion fan motor fault
63 Recirculation low flow
65 Water flow control device (servo) fault
70 Control board (PC board) fault
71 Gas solenoid valve circuit fault
72 Flame rod (flame sensing) fault
73 Burner thermocouple fault
79 Water leak detected inside the unit
LC Scale buildup in the heat exchanger
SS Service soon (maintenance reminder)
FF Maintenance has been performed (service history marker)

All Rinnai error codes