Rinnai code 63: recirculation low flow
Short answer
Code 63 means the recirculation system is not moving enough water. Rinnai's checklist covers clogged inlet and bypass filters, closed valves, air in the plumbing, the pump's power supply, loop length and the recirculation settings. A leak in the home's plumbing can also pull air into the loop.
Many Rinnai models include a recirculation pump that keeps hot water moving through a loop so it arrives at the tap faster. Code 63 means the heater expected recirculation flow and did not get enough.
Rinnai makes several generations of tankless heaters (SENSEI, SENSEI RX/CX and older non-SENSEI models). The meaning below comes from Rinnai's own diagnostic code guide; the exact service steps differ slightly between generations.
What to check first
- Make sure the cold inlet and hot outlet isolation valves under the heater are fully open.
- Turn off the water, drain the unit and clean the inlet filter and, on crossover setups, the bypass filter.
- Purge air from the lines by running each hot tap until the water flows smoothly with no sputtering.
Other causes Rinnai lists
- Wrong recirculation setting. The heater has to be set for the type of system installed: none, a dedicated return line or crossover. A unit set for recirculation with no pump connected will show this code.
- No power to the pump. The pump should receive 120 volts.
- A loop that is too long. Rinnai gives a maximum equivalent length of about 400 feet with 3/4-inch pipe or 100 feet with 1/2-inch pipe.
- A leak in the house plumbing. Rinnai explains that when the pump draws more water than a leak lets in, it can pull air into the system. A pressure test on the house plumbing will show it.
How to reset it
- Close all hot water taps.
- Turn the water heater off at the temperature controller, wait about a minute, then turn it back on.
- Open a hot tap and watch whether the code returns.
If the same code comes back, the cause is still there. Resetting over and over is not a repair.
When to call a technician
Settings, pump testing and plumbing pressure tests are best done by the installer, especially if the code started right after a new installation or a plumbing repair.
See the full list on our Rinnai error codes page.
Common questions
Can air in the pipes cause Rinnai code 63?
Yes. Air trapped in the recirculation loop is one of the most common causes. Purging the lines often clears it.
Will my Rinnai still make hot water with code 63?
In many cases the heater still works at the tap, but recirculation stops until the problem is fixed.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rinnai codes
| Code | Meaning |
|---|---|
| 02 | No burner operation during freeze protection |
| 03 | Power interruption during bath fill |
| 05 | Bypass flow control device fault |
| 10 | Air supply, exhaust blockage or condensate trap full |
| 11 | No ignition |
| 12 | Flame failure |
| 14 | Thermal fuse or overheat sensor tripped |
| 15 | Venturi control fault |
| 16 | Outgoing water temperature too high (safety shutdown) |
| 17 | Venturi blockage |
| 19 | Electrical grounding fault |
| 21 | Data transfer error after a control board replacement |
| 25 | Condensate drain clogged or condensate pump error |
| 32 | Outgoing water temperature sensor (thermistor) fault |
| 33 | Heat exchanger temperature sensor (thermistor) fault |
| 34 | Combustion air temperature sensor fault |
| 38 | Exhaust gas temperature sensor fault |
| 41 | Freeze protection sensor fault |
| 51 | Inlet water temperature sensor fault |
| 52 | Gas valve or modulating solenoid valve signal fault |
| 54 | High exhaust gas temperature |
| 57 | Burner overheat switch open |
| 58 | Secondary heat exchanger overheat |
| 61 | Combustion fan motor fault |
| 63 | Recirculation low flow |
| 65 | Water flow control device (servo) fault |
| 70 | Control board (PC board) fault |
| 71 | Gas solenoid valve circuit fault |
| 72 | Flame rod (flame sensing) fault |
| 73 | Burner thermocouple fault |
| 79 | Water leak detected inside the unit |
| LC | Scale buildup in the heat exchanger |
| SS | Service soon (maintenance reminder) |
| FF | Maintenance has been performed (service history marker) |