Rinnai LC code: scale buildup, what it means and how to clear it
Short answer
LC means the Rinnai has detected scale buildup in the heat exchanger. On older models the heater keeps running while the display alternates between LC and the temperature. On newer models LC can lock the heater out: pressing ON/OFF five times allows about 70 hours of temporary use, and the number after LC counts those resets. Flushing the heat exchanger is the real fix.
In this guide
LC stands for lime scale. When minerals from hard water coat the inside of the heat exchanger, the Rinnai detects it and shows LC, sometimes with a number from 0 to 9. In the unit's code history, LC can appear as 00.
Rinnai's diagnostic guide describes LC this way, and how it behaves depends on the age of the heater.
Older models: a warning
On older products, LC is the only code that lets the heater keep running. The display alternates between LC and the set temperature, and the controller beeps. Turning the power off and back on resets the code, but it returns until the scale is removed.
Newer models: a lockout
Newer products have a shutdown feature to prevent scale damage. LC locks the heater out and needs a reset.
- Temporary use: pressing ON/OFF on the temperature controller five times lets the heater run for about 70 hours. Then it locks out again with another LC code.
- What the number means: it counts those temporary resets. Rinnai's example: LC2 means the heater has been reset for three 70-hour periods without a flush.
- Full reset after flushing: a technician presses the two switches (A and B) on the PC board together for five seconds, which returns the heater to normal and sets the LC count back to 0. Rinnai notes this step is not in the owner's manual.
How to clear it properly
- Flush the heat exchanger using the procedure in your Rinnai manual, or follow our guide to descale a tankless water heater.
- Clean the inlet water filter while the unit is isolated.
- Reset the code: power cycle on older models, or have the board reset done on newer models.
Why LC keeps coming back
If LC returns within months, your water is hard enough that yearly flushing is not enough. Rinnai says hard water must be treated to prevent scale damage. A water softener or a scale-prevention filter on the cold supply slows scale buildup, and a lower temperature setting helps too.
When to call a technician
Call a technician if you cannot descale the unit yourself, if LC returns within months of a proper descaling, or if overheating codes such as 14 or 16 start to appear. A quick return means scale is still building up faster than maintenance removes it.
What happens if you ignore it
Scale insulates the heat exchanger, so the metal runs hotter. Left alone, it can lead to overheating codes such as 14 or 16 and shorten the life of the heat exchanger, the most expensive part of the heater. Using the 70-hour override again and again only delays that.
See every code on our Rinnai error codes page.
Common questions
How do I reset the LC code on a Rinnai?
Flush the heat exchanger first. Older models reset when power is cycled. Newer models need a reset on the control board, which a technician does by pressing the A and B switches together for five seconds.
Can I keep using my Rinnai with an LC code?
For a short time. On newer models, pressing ON/OFF five times allows about 70 hours of use before it locks out again. Flush it soon.
What does LC0 or LC2 mean?
The number counts how many times the heater has been temporarily reset without a flush. LC2 means three 70-hour periods.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rinnai codes
| Code | Meaning |
|---|---|
| 02 | No burner operation during freeze protection |
| 03 | Power interruption during bath fill |
| 05 | Bypass flow control device fault |
| 10 | Air supply, exhaust blockage or condensate trap full |
| 11 | No ignition |
| 12 | Flame failure |
| 14 | Thermal fuse or overheat sensor tripped |
| 15 | Venturi control fault |
| 16 | Outgoing water temperature too high (safety shutdown) |
| 17 | Venturi blockage |
| 19 | Electrical grounding fault |
| 21 | Data transfer error after a control board replacement |
| 25 | Condensate drain clogged or condensate pump error |
| 32 | Outgoing water temperature sensor (thermistor) fault |
| 33 | Heat exchanger temperature sensor (thermistor) fault |
| 34 | Combustion air temperature sensor fault |
| 38 | Exhaust gas temperature sensor fault |
| 41 | Freeze protection sensor fault |
| 51 | Inlet water temperature sensor fault |
| 52 | Gas valve or modulating solenoid valve signal fault |
| 54 | High exhaust gas temperature |
| 57 | Burner overheat switch open |
| 58 | Secondary heat exchanger overheat |
| 61 | Combustion fan motor fault |
| 63 | Recirculation low flow |
| 65 | Water flow control device (servo) fault |
| 70 | Control board (PC board) fault |
| 71 | Gas solenoid valve circuit fault |
| 72 | Flame rod (flame sensing) fault |
| 73 | Burner thermocouple fault |
| 79 | Water leak detected inside the unit |
| LC | Scale buildup in the heat exchanger |
| SS | Service soon (maintenance reminder) |
| FF | Maintenance has been performed (service history marker) |