Rinnai code 16: water too hot, causes and fixes
Short answer
Code 16 is a safety shutdown: the outgoing water temperature went above about 203°F (95°C). Rinnai's checklist points to restricted airflow at the vent, fan problems, debris in the combustion chamber, a blocked heat exchanger and a wrong gas type setting, with the gas valve or fan replaced if those check out.
Code 16 means the water leaving your Rinnai got far hotter than the temperature you set. Rinnai's diagnostic guide describes it as a high outgoing water temperature shutdown, triggered when outlet water passes 203°F (95°C).
That is a scald risk, so the unit stops heating. It is not a code to keep resetting.
Rinnai makes several generations of tankless heaters (SENSEI, SENSEI RX/CX and older non-SENSEI models). The meaning below comes from Rinnai's own diagnostic code guide; the exact service steps differ slightly between generations.
What causes code 16
- Restricted airflow. A blocked vent terminal or a problem with the combustion fan upsets the burn and the temperature control.
- A stuck check valve behind the fan that restricts air on newer SENSEI models.
- Debris in the combustion chamber or exhaust piping.
- A blocked heat exchanger. Scale inside or buildup between the fins keeps heat from transferring evenly.
- Wrong gas type setting. A unit set for natural gas but running on propane, or the reverse, will not burn correctly.
- A failing gas valve or fan motor, which Rinnai lists as the parts to replace once everything else checks out.
What you can check
- Look at the vent terminal outside and clear any leaves, nests, snow or ice.
- Think back to the last time the unit was descaled. If it has been more than a year in a hard water area, scale is a likely suspect.
- Check the cold water inlet filter; a clogged filter reduces flow through the heat exchanger.
If you smell gas, do not reset the unit or touch any switches. Leave the building and call your gas utility from outside.
When to call a technician
Fan tests, gas type settings, the gas valve and the heat exchanger all sit inside the sealed unit. If code 16 returns after you clear the vent, have a licensed installer inspect it. If scale is the cause, the fix may be as simple as learning to descale a tankless water heater and doing it on schedule.
See the full list on our Rinnai error codes page.
Common questions
Is Rinnai code 16 dangerous?
It means the water got hot enough to scald, so the unit shut itself off. Leave it off until the cause is found.
Can scale cause Rinnai code 16?
Yes. Scale in the heat exchanger makes heating uneven and can cause temperature spikes. Regular descaling helps prevent it.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rinnai codes
| Code | Meaning |
|---|---|
| 02 | No burner operation during freeze protection |
| 03 | Power interruption during bath fill |
| 05 | Bypass flow control device fault |
| 10 | Air supply, exhaust blockage or condensate trap full |
| 11 | No ignition |
| 12 | Flame failure |
| 14 | Thermal fuse or overheat sensor tripped |
| 15 | Venturi control fault |
| 16 | Outgoing water temperature too high (safety shutdown) |
| 17 | Venturi blockage |
| 19 | Electrical grounding fault |
| 21 | Data transfer error after a control board replacement |
| 25 | Condensate drain clogged or condensate pump error |
| 32 | Outgoing water temperature sensor (thermistor) fault |
| 33 | Heat exchanger temperature sensor (thermistor) fault |
| 34 | Combustion air temperature sensor fault |
| 38 | Exhaust gas temperature sensor fault |
| 41 | Freeze protection sensor fault |
| 51 | Inlet water temperature sensor fault |
| 52 | Gas valve or modulating solenoid valve signal fault |
| 54 | High exhaust gas temperature |
| 57 | Burner overheat switch open |
| 58 | Secondary heat exchanger overheat |
| 61 | Combustion fan motor fault |
| 63 | Recirculation low flow |
| 65 | Water flow control device (servo) fault |
| 70 | Control board (PC board) fault |
| 71 | Gas solenoid valve circuit fault |
| 72 | Flame rod (flame sensing) fault |
| 73 | Burner thermocouple fault |
| 79 | Water leak detected inside the unit |
| LC | Scale buildup in the heat exchanger |
| SS | Service soon (maintenance reminder) |
| FF | Maintenance has been performed (service history marker) |