Rinnai code 57: burner overheat switch

Short answer

Code 57 means one of two bi-metal overheat switches on the back of the burner opened. It applies to older non-SENSEI models and appears even when the heater is idle. Rinnai's checks cover the switch wiring, correct gas type, manifold gas pressures and any past gas conversion. The code clears only with a hard reset after the fix.

In this guide
  1. Why a normal reset may not clear it
  2. What Rinnai tells technicians to check
  3. What homeowners can do
  4. Before you call

A bi-metal switch is a simple safety device that opens when it gets too hot. Rinnai puts two of them on the back of the burner assembly. Code 57 means at least one has opened.

The meaning and service steps below come from Rinnai's own diagnostic code guide for its tankless water heaters.

Rinnai lists this code for its non-SENSEI series.

Why a normal reset may not clear it

Rinnai explains that this code stays on even when the heater is idle. It clears only after the cause is fixed and the power to the unit is switched off and back on, which Rinnai calls a hard reset.

If you smell gas, do not reset the unit or touch any switches. Leave the building and call your gas utility from outside.

What Rinnai tells technicians to check

  • The switch wiring back to the control board
  • That the heater is connected to the gas type it was built for
  • That low and high fire manifold pressures are set correctly for the altitude
  • That any conversion from one gas type to another was done exactly per the manufacturer's instructions

What homeowners can do

Very little on this code. It points to how the burner is being fueled, which is qualified gas technician work. Leave the unit off, and mention if it was ever converted between natural gas and propane.

Before you call

Have the model and serial number from the rating label ready, along with the exact code and when it appears: at startup, during use, or only at high demand. Mention any recent work on the gas, water or electrical supply and when the heater was last descaled. This helps the technician bring the right parts and often saves a second visit.

See every code on our Rinnai error codes page.

Common questions

Can I just reset Rinnai code 57?

Only after the cause is fixed. The code survives a normal reset and needs a power-off hard reset once the problem is corrected.

Was this article helpful?

Other Rinnai codes

CodeMeaning
02 No burner operation during freeze protection
03 Power interruption during bath fill
05 Bypass flow control device fault
10 Air supply, exhaust blockage or condensate trap full
11 No ignition
12 Flame failure
14 Thermal fuse or overheat sensor tripped
15 Venturi control fault
16 Outgoing water temperature too high (safety shutdown)
17 Venturi blockage
19 Electrical grounding fault
21 Data transfer error after a control board replacement
25 Condensate drain clogged or condensate pump error
32 Outgoing water temperature sensor (thermistor) fault
33 Heat exchanger temperature sensor (thermistor) fault
34 Combustion air temperature sensor fault
38 Exhaust gas temperature sensor fault
41 Freeze protection sensor fault
51 Inlet water temperature sensor fault
52 Gas valve or modulating solenoid valve signal fault
54 High exhaust gas temperature
57 Burner overheat switch open
58 Secondary heat exchanger overheat
61 Combustion fan motor fault
63 Recirculation low flow
65 Water flow control device (servo) fault
70 Control board (PC board) fault
71 Gas solenoid valve circuit fault
72 Flame rod (flame sensing) fault
73 Burner thermocouple fault
79 Water leak detected inside the unit
LC Scale buildup in the heat exchanger
SS Service soon (maintenance reminder)
FF Maintenance has been performed (service history marker)