Rinnai water heater error codes
How to read the codes
Rinnai tankless water heaters show a two-digit number, or a code like LC or SS, on the temperature controller when something stops the unit. Find your code in the table, then use the full guide where one is linked.
All Rinnai codes
| Code | Meaning |
|---|---|
| 02 | No burner operation during freeze protection Full guide |
| 03 | Power interruption during bath fill Full guide |
| 05 | Bypass flow control device fault Full guide |
| 07 | Circulation flow rate too low (hybrid RH180 models) |
| 10 | Air supply, exhaust blockage or condensate trap full Full guide |
| 11 | No ignition Full guide |
| 12 | Flame failure Full guide |
| 13 | Combustion fault (hybrid RH180 models) |
| 14 | Thermal fuse or overheat sensor tripped Full guide |
| 15 | Venturi control fault Full guide |
| 16 | Outgoing water temperature too high (safety shutdown) Full guide |
| 17 | Venturi blockage Full guide |
| 18 | Gas valve adjustment limit |
| 19 | Electrical grounding fault Full guide |
| 21 | Data transfer error after a control board replacement Full guide |
| 22 | Gas valve adjustment fault |
| 25 | Condensate drain clogged or condensate pump error Full guide |
| 30 | Flammable vapor sensor (hybrid RH180 models) |
| 31 | Burner thermocouple fault (RH180 hybrid models) |
| 32 | Outgoing water temperature sensor (thermistor) fault Full guide |
| 33 | Heat exchanger temperature sensor (thermistor) fault Full guide |
| 34 | Combustion air temperature sensor fault Full guide |
| 35 | Tank temperature sensor (hybrid RH180 models) |
| 38 | Exhaust gas temperature sensor fault Full guide |
| 41 | Freeze protection sensor fault Full guide |
| 51 | Inlet water temperature sensor fault Full guide |
| 52 | Gas valve or modulating solenoid valve signal fault Full guide |
| 54 | High exhaust gas temperature Full guide |
| 57 | Burner overheat switch open Full guide |
| 58 | Secondary heat exchanger overheat Full guide |
| 61 | Combustion fan motor fault Full guide |
| 63 | Recirculation low flow Full guide |
| 65 | Water flow control device (servo) fault Full guide |
| 66 | Bypass flow servo fault (SENSEI RX models) |
| 70 | Control board (PC board) fault Full guide |
| 71 | Gas solenoid valve circuit fault Full guide |
| 72 | Flame rod (flame sensing) fault Full guide |
| 73 | Burner thermocouple fault Full guide |
| 79 | Water leak detected inside the unit Full guide |
| LC | Scale buildup in the heat exchanger Full guide |
| SS | Service soon (maintenance reminder) Full guide |
| FF | Maintenance has been performed (service history marker) Full guide |
| FE | Flammable vapors detected (hybrid RH180 models) |
| SE | Error on a secondary unit in a cascaded commercial system |
Most Rinnai codes are a safety shutdown: the unit found a condition it does not like, turned off the gas and is telling you which system was involved. The number points you to the right area to check. It does not always name the failed part.
A handful of codes are common and have simple causes a homeowner can check. The rest point to sensors, wiring or the control board and need a technician.
If you smell gas, do not reset the unit or touch any switches. Leave the building and call your gas utility from outside.
How to reset a Rinnai error code
- Turn off all hot water taps.
- Press the ON/OFF button on the temperature controller to turn the unit off, then press it again to turn it back on.
- Open a hot water tap to see whether the unit fires normally.
If the code comes back, the cause is still there. Repeatedly resetting a unit with a combustion or overheating code is not a fix, and it can hide a problem that gets worse.
The codes homeowners see most
Gas and ignition: 11 and 12
Code 11 means the burner did not light, and code 12 means it lit and then lost the flame. Both usually start with the gas supply: a closed valve, an empty propane tank, air in a new gas line or a gas line too small for the heater.
Air and venting: 10
Code 10 points to the air supply or exhaust. Check the vent terminal outside for snow, ice, leaves or nests. On condensing SENSEI models it can also mean the condensate drain is blocked or frozen.
Overheating: 14, 16, 54, 57 and 58
These codes mean part of the unit got too hot. Scale inside the heat exchanger and venting problems are the usual causes. They should be taken seriously and looked at by a technician.
Maintenance: LC and SS
LC means scale is building up in the heat exchanger and the unit needs to be flushed. SS is a service reminder set by the installer. Neither means the heater has failed, but LC in particular should not be ignored.
What you can safely check yourself
- That the gas valve to the heater is open and other gas appliances work.
- The propane tank level, if you use propane.
- The outside vent terminal, for blockages.
- The condensate drain line on condensing models, for kinks, clogs or ice.
- The inlet water filter, which can clog and reduce flow.
- When the unit was last descaled.
When to call a technician
Rinnai's troubleshooting procedures for most codes involve gas pressure testing, measuring sensor resistance and opening the sealed combustion area. Rinnai limits those steps to trained professionals, and doing them yourself can affect the warranty. If a code returns after a reset and the simple checks above do not explain it, call a Rinnai-trained installer.
Common questions
How do I find the last error codes on my Rinnai?
Many Rinnai controllers can display recent maintenance codes. The button sequence differs between models, so check the owner's manual or ask your installer.
Why does my Rinnai show LC but still make hot water?
LC is a warning that scale is building up. The unit keeps running for a while so you have time to flush it, but repeated LC codes can eventually lock the heater out.
Are Rinnai error codes the same on every model?
Most common codes, like 10, 11, 12 and LC, mean the same thing across models. Some codes only apply to certain series, such as the RH180 hybrid or SENSEI condensing units.