Rinnai 38

Rinnai code 38: exhaust gas temperature sensor fault

Short answer

Code 38 is an exhaust gas temperature sensor fault on Rinnai SENSEI and non-SENSEI tankless heaters. Rinnai's steps are to check the sensor wiring, remove the sensor and test its resistance, reinstall it and test again, then check gas type, any gas conversion, clearances, settings, manifold gas pressures, the burner, heat exchanger fins and venting before replacing the sensor.

In this guide
  1. Sensor checks
  2. If code 38 continues
  3. RH180 hybrid models
  4. Before you call

The exhaust gas temperature sensor watches how hot the exhaust leaving the heater is. That protects the vent and helps the heater catch combustion problems. Code 38 means the sensor, or what it is reading, is outside the expected range.

The meaning and steps below come from Rinnai's own diagnostic code guide for its tankless water heaters.

Sensor checks

  1. Inspect the wiring harness at the sensor and at the control board.
  2. Remove the sensor and measure its resistance. Rinnai lists values such as about 11,400 to 14,000 ohms at 59°F; the reading should fall as the sensor warms.
  3. If the readings are right, reinstall it in the exhaust port and run the heater.

If code 38 continues

  • Confirm the heater runs on the gas type shown on its rating plate, and that any gas conversion was done exactly per Rinnai's instructions.
  • Check clearances around the heater and vent terminals.
  • Confirm the parameter or DIP switch settings for the installation.
  • Have manifold gas pressures checked with a manometer.
  • Inspect the burner and heat exchanger fins for debris, and the venting for correct length and clearances.
  • Replace the sensor if nothing else explains the code.

If you smell gas, do not reset the unit. Leave the building and call your gas utility from outside.

RH180 hybrid models

On Rinnai's RH180 hybrid tank-tankless heater, the diagnostic guide ties code 38 to the carbon monoxide sensor, with combustion air, B-vent venting and gas pressure checks. Make sure working CO alarms are installed in the home.

Before you call

Have the model and serial number from the rating label ready, and note whether your unit is a SENSEI or an older non-SENSEI model. Tell the technician the exact code, when it appears and any recent service or parts replacement. That often saves a second visit.

See every code on our Rinnai error codes page.

Common questions

Is Rinnai code 38 dangerous?

It is a sensor code, but it can point to combustion or venting problems. Have it checked promptly and keep CO alarms working.

Was this article helpful?

Other Rinnai codes

CodeMeaning
02 No burner operation during freeze protection
03 Power interruption during bath fill
05 Bypass flow control device fault
10 Air supply, exhaust blockage or condensate trap full
11 No ignition
12 Flame failure
14 Thermal fuse or overheat sensor tripped
15 Venturi control fault
16 Outgoing water temperature too high (safety shutdown)
17 Venturi blockage
19 Electrical grounding fault
21 Data transfer error after a control board replacement
25 Condensate drain clogged or condensate pump error
32 Outgoing water temperature sensor (thermistor) fault
33 Heat exchanger temperature sensor (thermistor) fault
34 Combustion air temperature sensor fault
38 Exhaust gas temperature sensor fault
41 Freeze protection sensor fault
51 Inlet water temperature sensor fault
52 Gas valve or modulating solenoid valve signal fault
54 High exhaust gas temperature
57 Burner overheat switch open
58 Secondary heat exchanger overheat
61 Combustion fan motor fault
63 Recirculation low flow
65 Water flow control device (servo) fault
70 Control board (PC board) fault
71 Gas solenoid valve circuit fault
72 Flame rod (flame sensing) fault
73 Burner thermocouple fault
79 Water leak detected inside the unit
LC Scale buildup in the heat exchanger
SS Service soon (maintenance reminder)
FF Maintenance has been performed (service history marker)