Rinnai 72

Rinnai code 72: flame rod fault

Short answer

Code 72 is a flame rod fault. The flame rod proves to the control board that the burner is lit. Rinnai's steps are to check the wiring, make sure the rod sits in the flame, remove it and look for carbon buildup, measure its microamp signal, replace the rod and gasket, and check for a leaking heat exchanger.

In this guide
  1. Common causes
  2. What a technician does
  3. How to reset it
  4. Why carbon builds up

The flame rod is a small metal probe that sits in the burner flame. A tiny electrical current passes through the flame, and that current tells the control board the burner is really lit. Code 72 means the board is not getting a reliable signal from it.

Rinnai makes several generations of tankless heaters (SENSEI, SENSEI RX/CX and older non-SENSEI models). The meaning below comes from Rinnai's own diagnostic code guide; the exact service steps differ slightly between generations.

Common causes

  • Carbon buildup on the rod, which weakens the signal
  • A rod that has shifted and no longer touches the flame
  • Damaged wiring between the rod and the control board
  • A leaking heat exchanger dripping water into the burner area, which Rinnai lists as something to rule out
  • A control board fault, once the rod and wiring check out

What a technician does

Rinnai's guide calls for measuring the flame rod's output, which should hold at least 1 microamp. If it is low, the rod is cleaned or, more often, replaced along with its gasket. The technician also checks that the heat exchanger is not leaking.

How to reset it

  1. Close all hot water taps.
  2. Turn the water heater off at the temperature controller, wait about a minute, then turn it back on.
  3. Open a hot tap and watch whether the code returns.

If the same code comes back, the cause is still there. Resetting over and over is not a repair.

Why carbon builds up

Carbon on the flame rod usually points to a burn that is not quite right, from restricted airflow, a dirty burner or venting problems. If the rod keeps fouling, ask the technician to look at combustion as well as replacing the part.

See the full list on our Rinnai error codes page.

Common questions

Can I clean a Rinnai flame rod myself?

It sits inside the sealed combustion area, so cleaning or replacing it is a job for a qualified technician.

Is code 72 related to code 11 or 12?

They are related. Codes 11 and 12 are ignition and flame failures, and a weak flame rod signal can play a part in all three.

Was this article helpful?

Other Rinnai codes

CodeMeaning
02 No burner operation during freeze protection
03 Power interruption during bath fill
05 Bypass flow control device fault
10 Air supply, exhaust blockage or condensate trap full
11 No ignition
12 Flame failure
14 Thermal fuse or overheat sensor tripped
15 Venturi control fault
16 Outgoing water temperature too high (safety shutdown)
17 Venturi blockage
19 Electrical grounding fault
21 Data transfer error after a control board replacement
25 Condensate drain clogged or condensate pump error
32 Outgoing water temperature sensor (thermistor) fault
33 Heat exchanger temperature sensor (thermistor) fault
34 Combustion air temperature sensor fault
38 Exhaust gas temperature sensor fault
41 Freeze protection sensor fault
51 Inlet water temperature sensor fault
52 Gas valve or modulating solenoid valve signal fault
54 High exhaust gas temperature
57 Burner overheat switch open
58 Secondary heat exchanger overheat
61 Combustion fan motor fault
63 Recirculation low flow
65 Water flow control device (servo) fault
70 Control board (PC board) fault
71 Gas solenoid valve circuit fault
72 Flame rod (flame sensing) fault
73 Burner thermocouple fault
79 Water leak detected inside the unit
LC Scale buildup in the heat exchanger
SS Service soon (maintenance reminder)
FF Maintenance has been performed (service history marker)

All Rinnai error codes