Rinnai 79
Rinnai code 79: water leak detected
Short answer
Code 79 means the leak sensor in the bottom of the heater detected water. Rinnai's steps are to check the sensor wiring, look for leaks at the heat exchanger and internal piping, dry any water in the cabinet and dry the sensor, and replace the sensor if the unit runs with it unplugged and no leak is found.
In this guide
Some Rinnai models have a leak sensor in the bottom of the cabinet. When it gets wet, the unit shuts down and shows code 79 so a small leak does not turn into a big one.
According to Rinnai's diagnostic guide, this code applies to non-SENSEI models.
What to do first
- Turn the heater off at the controller.
- Look under and around the unit for water. Check the pipe connections below it, the pressure relief valve and the vent above it.
- If water is dripping from a connection, close the cold water isolation valve under the heater.
Where the water can come from
- A leaking heat exchanger or internal pipe joint. Rinnai lists these first.
- A loose external connection dripping into the cabinet.
- Condensation or rain entering through the vent.
- A false alarm from a faulty sensor, when no water is found anywhere.
What a technician does
With the cover off, the technician checks the heat exchanger and internal piping, wipes or blows out any water, dries the sensor and restarts the unit. If there is no water but the code persists, the sensor is unplugged as a test. If the heater runs normally without it, the sensor and its screw are replaced.
If the heat exchanger is leaking
A leaking heat exchanger is usually the most expensive repair on a tankless unit. Check whether it is still under warranty, and on an older unit compare the quote with a replacement. Scale and freezing are two common reasons heat exchangers fail, so protect a new one with regular descaling and freeze protection.
See the full list on our Rinnai error codes page.
Common questions
Can I ignore Rinnai code 79 if I do not see water?
Do not ignore it. Have the inside of the cabinet checked. If no leak is found, the sensor may be faulty and can be replaced.
Does homeowners insurance cover a leaking tankless heater?
Policies differ. Many cover sudden water damage but not the failed appliance itself. Check with your insurer.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rinnai codes
| Code | Meaning |
|---|---|
| 02 | No burner operation during freeze protection |
| 03 | Power interruption during bath fill |
| 05 | Bypass flow control device fault |
| 10 | Air supply, exhaust blockage or condensate trap full |
| 11 | No ignition |
| 12 | Flame failure |
| 14 | Thermal fuse or overheat sensor tripped |
| 15 | Venturi control fault |
| 16 | Outgoing water temperature too high (safety shutdown) |
| 17 | Venturi blockage |
| 19 | Electrical grounding fault |
| 21 | Data transfer error after a control board replacement |
| 25 | Condensate drain clogged or condensate pump error |
| 32 | Outgoing water temperature sensor (thermistor) fault |
| 33 | Heat exchanger temperature sensor (thermistor) fault |
| 34 | Combustion air temperature sensor fault |
| 38 | Exhaust gas temperature sensor fault |
| 41 | Freeze protection sensor fault |
| 51 | Inlet water temperature sensor fault |
| 52 | Gas valve or modulating solenoid valve signal fault |
| 54 | High exhaust gas temperature |
| 57 | Burner overheat switch open |
| 58 | Secondary heat exchanger overheat |
| 61 | Combustion fan motor fault |
| 63 | Recirculation low flow |
| 65 | Water flow control device (servo) fault |
| 70 | Control board (PC board) fault |
| 71 | Gas solenoid valve circuit fault |
| 72 | Flame rod (flame sensing) fault |
| 73 | Burner thermocouple fault |
| 79 | Water leak detected inside the unit |
| LC | Scale buildup in the heat exchanger |
| SS | Service soon (maintenance reminder) |
| FF | Maintenance has been performed (service history marker) |