Rinnai 32

Rinnai code 32: outgoing water temperature sensor fault

Short answer

Code 32 is a fault with the outgoing water temperature thermistor, the sensor that tells the heater how hot the water leaving it is. Rinnai's steps are to check the sensor wiring, remove the sensor and clean off any scale, test its resistance, and replace it if the code returns.

In this guide
  1. Common causes
  2. What a technician does
  3. How to reset it
  4. Preventing it

A tankless heater adjusts its burner second by second based on how hot the outgoing water is. That reading comes from a thermistor, a small sensor whose electrical resistance changes with temperature. When the reading makes no sense to the control board, the unit shows code 32.

Rinnai makes several generations of tankless heaters (SENSEI, SENSEI RX/CX and older non-SENSEI models). The meaning below comes from Rinnai's own diagnostic code guide; the exact service steps differ slightly between generations.

Common causes

  • Scale on the sensor. Rinnai's service steps include removing the thermistor and cleaning any buildup off it. In hard water areas, scale is a frequent culprit.
  • Loose or damaged wiring between the sensor and the control board.
  • A failed sensor. A technician tests it with a meter; its resistance should drop smoothly as it warms.

What a technician does

  1. Checks the wiring harness from the sensor to the board.
  2. Shuts off the water, drains the unit, removes the sensor and cleans it.
  3. Measures its resistance against Rinnai's reference values.
  4. Reinstalls it with its O-ring intact, checks for leaks and fires the unit. If code 32 returns, the sensor is replaced.

On some recirculating models Rinnai also lists a check valve in the internal circulation piping as a possible cause.

How to reset it

  1. Close all hot water taps.
  2. Turn the water heater off at the temperature controller, wait about a minute, then turn it back on.
  3. Open a hot tap and watch whether the code returns.

If the same code comes back, the cause is still there. Resetting over and over is not a repair.

Preventing it

Because scale plays a part, keeping up with maintenance matters. If you have hard water, plan to descale a tankless water heater about once a year, or as often as your manual recommends.

See the full list on our Rinnai error codes page.

Common questions

Is a Rinnai thermistor expensive?

The sensor is an inexpensive part. Most of the cost is the service call and the labor to drain the unit and test it.

Can I still use hot water with code 32?

Usually not. Without a valid temperature reading, the heater will not run normally.

Was this article helpful?

Other Rinnai codes

CodeMeaning
02 No burner operation during freeze protection
03 Power interruption during bath fill
05 Bypass flow control device fault
10 Air supply, exhaust blockage or condensate trap full
11 No ignition
12 Flame failure
14 Thermal fuse or overheat sensor tripped
15 Venturi control fault
16 Outgoing water temperature too high (safety shutdown)
17 Venturi blockage
19 Electrical grounding fault
21 Data transfer error after a control board replacement
25 Condensate drain clogged or condensate pump error
32 Outgoing water temperature sensor (thermistor) fault
33 Heat exchanger temperature sensor (thermistor) fault
34 Combustion air temperature sensor fault
38 Exhaust gas temperature sensor fault
41 Freeze protection sensor fault
51 Inlet water temperature sensor fault
52 Gas valve or modulating solenoid valve signal fault
54 High exhaust gas temperature
57 Burner overheat switch open
58 Secondary heat exchanger overheat
61 Combustion fan motor fault
63 Recirculation low flow
65 Water flow control device (servo) fault
70 Control board (PC board) fault
71 Gas solenoid valve circuit fault
72 Flame rod (flame sensing) fault
73 Burner thermocouple fault
79 Water leak detected inside the unit
LC Scale buildup in the heat exchanger
SS Service soon (maintenance reminder)
FF Maintenance has been performed (service history marker)