Rheem 03

Rheem code 03: communication failure

Short answer

Code 03 on current Rheem and Ruud tankless heaters means communication failed between water heaters, the remote control and/or a manifold controller. It mostly appears on systems with two or more linked units. Rheem's steps include checking the communication wiring and confirming the DIP1 settings on the control board.

In this guide
  1. What it means by model generation
  2. What a technician checks
  3. What you can do
  4. How to reset it
  5. Before you call

Larger homes and commercial systems sometimes link several tankless heaters so they work as one. Code 03 means the units, or their controls, have stopped talking to each other.

This page uses two Rheem sources: the current Rheem and Ruud tankless troubleshooting manual, and Rheem's error code list for earlier tankless models. Codes can differ between generations, so the meaning for each is shown where they differ. Rheem technical support: (800) 432-8373.

What it means by model generation

Rheem generationMeaning
Current modelsCommunication failure between water heaters, remote control and/or manifold controller

What a technician checks

  • The communication cables between units and the manifold controller, for loose, damaged or reversed connections
  • The DIP1 switch settings on each control board, which tell each unit its role in the system
  • The remote control wiring
  • Whether a control board has failed

What you can do

  1. Note whether work was done near the units or their wiring recently.
  2. Turn the system off and on once.
  3. If code 03 returns, call a technician familiar with multi-unit systems.

How to reset it

  1. Close all hot water taps.
  2. Turn the remote control off, wait about 10 seconds, then turn it back on.
  3. Open a hot tap and watch whether the code returns.

Before you call

Have the model and serial number from the rating label ready, and note whether your unit is a condensing (high-efficiency) or non-condensing model. Tell the technician the exact code, when it appears and any recent work on the gas, water, venting or electrical supply. That often saves a second visit.

See every code on our Rheem error codes page.

Common questions

Does code 03 appear on single Rheem tankless units?

It is mainly a linked-system code. On a single unit, a remote wiring fault is more likely to show as code 76.

Was this article helpful?

Other Rheem codes

CodeMeaning
00 Continuous combustion for more than one hour
03 Communication failure between units, remote or manifold controller
05 Improper combustion detected by the flame rod (warning)
10 Air supply or exhaust blockage (hard lockout)
11 Ignition failure
12 Flame failure
13 Poor combustion detected by the flame rod (indoor units)
14 Overheat safety tripped
15 Heat exchanger or hot water temperature too high (boiling safety)
16 Outlet water temperature above the set point (over temperature warning)
21 Air intake filter switch fault (earlier models)
24 Remote control buttons held too long, or operational switch fault
29 Condensate not draining (condensing models) or heat exchanger temperature too low
31 Inlet water temperature sensor (thermistor) fault
32 Heat exchanger thermistor fault
33 Outlet (outgoing water) thermistor fault
34 Ambient or combustion air temperature sensor fault
35 Improper thermistor connection
51 Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier)
52 Modulating gas valve (PGFR) fault
61 Blower (combustion fan) motor fault
65 Water volume control valve fault
66 Water bypass valve fault
71 Gas inlet solenoid valve fault
72 Flame rod fault: flame sensed before ignition
76 Remote control communication fault
79 Blower (fan) motor current fault
80 Gas cut-off failure: flame detected after the unit turned off
82 Control board program chip fault (current) / gas type data failure (earlier)
90 Vent blockage detected before ignition
92 Neutralizer needs replacing soon (warning, condensing models)
93 Neutralizer must be replaced; unit will not operate (condensing models)
1L Lime (scale) buildup detected in the heat exchanger
99 Vent blockage detected after shutdown / blocked flue (hard lockout)
P1 Not enough water flow to fire the burner (warning)