Rheem 93
Rheem code 93: neutralizer replacement required
Short answer
Code 93 appears on high-efficiency (condensing) Rheem and Ruud tankless heaters. Rheem says the unit will not operate until the neutralizer is replaced, and the unit must be reset afterward. With the remote on and no water running, press MIN and MAX together until CL appears, then press them again for more than 5 seconds until CL disappears.
Code 93 follows code 92. Where 92 is the warning, 93 means the neutralizer is used up and the heater has stopped.
This page uses two Rheem sources: the current Rheem and Ruud tankless troubleshooting manual, and Rheem's error code list for earlier tankless models. Codes can differ between generations, so the meaning for each is shown where they differ. Rheem technical support: (800) 432-8373.
What it means by model generation
| Rheem generation | Meaning |
|---|---|
| Current models | Unit will not operate until the neutralizer is replaced |
What to do
- Replace the neutralizer with a kit from a Rheem or Ruud supplier. The media is calcium carbonate.
- Check the condensate drain line for blockage while you are there.
- Reset: remote on, no water running, press MIN and MAX together until CL appears, then again for more than 5 seconds until CL disappears.
Prevent it next time
Check the neutralizer at each yearly service, along with the flush and filter cleaning. A condensate drain problem, code 29 on condensing models, can also shut the heater down.
Before you call
Have the model and serial number from the rating label ready, and note whether your unit is a condensing (high-efficiency) or non-condensing model. Tell the technician the exact code, when it appears and any recent work on the gas, water, venting or electrical supply. That often saves a second visit.
See every code on our Rheem error codes page.
Common questions
Why won't my Rheem run with code 93?
Rheem designed it to stop until the neutralizer is replaced and the unit is reset.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rheem codes
| Code | Meaning |
|---|---|
| 00 | Continuous combustion for more than one hour |
| 03 | Communication failure between units, remote or manifold controller |
| 05 | Improper combustion detected by the flame rod (warning) |
| 10 | Air supply or exhaust blockage (hard lockout) |
| 11 | Ignition failure |
| 12 | Flame failure |
| 13 | Poor combustion detected by the flame rod (indoor units) |
| 14 | Overheat safety tripped |
| 15 | Heat exchanger or hot water temperature too high (boiling safety) |
| 16 | Outlet water temperature above the set point (over temperature warning) |
| 21 | Air intake filter switch fault (earlier models) |
| 24 | Remote control buttons held too long, or operational switch fault |
| 29 | Condensate not draining (condensing models) or heat exchanger temperature too low |
| 31 | Inlet water temperature sensor (thermistor) fault |
| 32 | Heat exchanger thermistor fault |
| 33 | Outlet (outgoing water) thermistor fault |
| 34 | Ambient or combustion air temperature sensor fault |
| 35 | Improper thermistor connection |
| 51 | Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier) |
| 52 | Modulating gas valve (PGFR) fault |
| 61 | Blower (combustion fan) motor fault |
| 65 | Water volume control valve fault |
| 66 | Water bypass valve fault |
| 71 | Gas inlet solenoid valve fault |
| 72 | Flame rod fault: flame sensed before ignition |
| 76 | Remote control communication fault |
| 79 | Blower (fan) motor current fault |
| 80 | Gas cut-off failure: flame detected after the unit turned off |
| 82 | Control board program chip fault (current) / gas type data failure (earlier) |
| 90 | Vent blockage detected before ignition |
| 92 | Neutralizer needs replacing soon (warning, condensing models) |
| 93 | Neutralizer must be replaced; unit will not operate (condensing models) |
| 1L | Lime (scale) buildup detected in the heat exchanger |
| 99 | Vent blockage detected after shutdown / blocked flue (hard lockout) |
| P1 | Not enough water flow to fire the burner (warning) |