Rheem 76

Rheem code 76: remote control communication fault

Short answer

Code 76 means the remote control is not communicating with the control board of a Rheem or Ruud tankless water heater. Rheem's steps are to inspect the remote wiring for damage or loose connections, then test the remote with a short new wire at the unit, which shows whether the wiring, the remote or the control board is at fault.

In this guide
  1. Common causes
  2. How Rheem narrows it down
  3. What you can do
  4. Before you call

The wall-mounted remote lets you set the temperature and see codes. It talks to the heater over a thin two-wire cable. Code 76 means that conversation has stopped.

The meaning and service steps below come from Rheem's tankless gas troubleshooting manual, which covers both Rheem and Ruud tankless water heaters. Rheem technical support: (800) 432-8373.

Common causes

  • Loose or corroded connections at the remote or at the terminals on the bottom of the heater
  • Damaged remote wiring, for example from a nail, a renovation or rodents
  • A failed remote control
  • A failed control board in the heater

How Rheem narrows it down

  1. Inspect the wiring and tighten or repair any loose or damaged connections.
  2. Disconnect the remote wires at the heater and see whether the unit fires on its own. If it does not, the control board is suspect.
  3. Connect the remote directly to the heater with a short new piece of wire. If code 76 disappears, the original wiring is bad. If it stays, the remote is replaced.

What you can do

Check whether any work was done near the remote's wiring recently, and look at the terminal screws under the heater for anything loose. Turn off power before touching the terminals.

Before you call

Have the model and serial number from the rating label ready, along with the exact code and when it appears: at startup, during use, or only at high demand. Mention any recent work on the gas, water or electrical supply and when the heater was last serviced. This helps the technician bring the right parts and often saves a second visit.

See every code on our Rheem error codes page.

Common questions

Will my Rheem still heat water with code 76?

Sometimes it keeps heating, but you lose control of the temperature from the remote. Get it fixed so you can see future codes.

Was this article helpful?

Other Rheem codes

CodeMeaning
00 Continuous combustion for more than one hour
03 Communication failure between units, remote or manifold controller
05 Improper combustion detected by the flame rod (warning)
10 Air supply or exhaust blockage (hard lockout)
11 Ignition failure
12 Flame failure
13 Poor combustion detected by the flame rod (indoor units)
14 Overheat safety tripped
15 Heat exchanger or hot water temperature too high (boiling safety)
16 Outlet water temperature above the set point (over temperature warning)
21 Air intake filter switch fault (earlier models)
24 Remote control buttons held too long, or operational switch fault
29 Condensate not draining (condensing models) or heat exchanger temperature too low
31 Inlet water temperature sensor (thermistor) fault
32 Heat exchanger thermistor fault
33 Outlet (outgoing water) thermistor fault
34 Ambient or combustion air temperature sensor fault
35 Improper thermistor connection
51 Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier)
52 Modulating gas valve (PGFR) fault
61 Blower (combustion fan) motor fault
65 Water volume control valve fault
66 Water bypass valve fault
71 Gas inlet solenoid valve fault
72 Flame rod fault: flame sensed before ignition
76 Remote control communication fault
79 Blower (fan) motor current fault
80 Gas cut-off failure: flame detected after the unit turned off
82 Control board program chip fault (current) / gas type data failure (earlier)
90 Vent blockage detected before ignition
92 Neutralizer needs replacing soon (warning, condensing models)
93 Neutralizer must be replaced; unit will not operate (condensing models)
1L Lime (scale) buildup detected in the heat exchanger
99 Vent blockage detected after shutdown / blocked flue (hard lockout)
P1 Not enough water flow to fire the burner (warning)

All Rheem error codes