Rheem code 71: gas inlet solenoid valve fault
Short answer
Code 71 is a gas inlet solenoid valve fault on Rheem and Ruud tankless heaters. Current models call it a gas control valve malfunction (inlet solenoid); earlier models call it a gas inlet solenoid valve control fault. Technicians reseat the connector, check the wiring, measure the solenoid resistance and replace the gas valve or control board.
In this guide
The inlet solenoid opens and closes the main gas supply to the burner. Code 71 means the control board detected a problem with it.
This page uses two Rheem sources: the current Rheem and Ruud tankless troubleshooting manual, and Rheem's error code list for earlier tankless models. Codes can differ between generations, so the meaning for each is shown where they differ. Rheem technical support: (800) 432-8373.
What it means by model generation
| Rheem generation | Meaning |
|---|---|
| Current models | Gas control valve malfunction (inlet solenoid) |
| Earlier models | Gas inlet solenoid valve control fault |
If you smell gas, do not reset the unit or touch switches. Leave the building and call your gas utility from outside.
What a technician checks
- The gas valve connector, removed and reinserted; Rheem notes a loose connection is a common cause
- The wiring harness for loose or damaged terminals
- Solenoid resistance
Depending on the results, the gas control valve or the control board is replaced.
What you can do
Reset once. If code 71 returns, call a qualified technician.
How to reset it
- Close all hot water taps.
- Turn the remote control off, wait about 10 seconds, then turn it back on.
- Open a hot tap and watch whether the code returns.
Before you call
Have the model and serial number from the rating label ready, and note whether your unit is a condensing (high-efficiency) or non-condensing model. Tell the technician the exact code, when it appears and any recent work on the gas, water, venting or electrical supply. That often saves a second visit.
See every code on our Rheem error codes page.
Common questions
Is Rheem code 71 a gas leak?
No. It is an electrical fault in the valve circuit. If you smell gas, leave and call the utility.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rheem codes
| Code | Meaning |
|---|---|
| 00 | Continuous combustion for more than one hour |
| 03 | Communication failure between units, remote or manifold controller |
| 05 | Improper combustion detected by the flame rod (warning) |
| 10 | Air supply or exhaust blockage (hard lockout) |
| 11 | Ignition failure |
| 12 | Flame failure |
| 13 | Poor combustion detected by the flame rod (indoor units) |
| 14 | Overheat safety tripped |
| 15 | Heat exchanger or hot water temperature too high (boiling safety) |
| 16 | Outlet water temperature above the set point (over temperature warning) |
| 21 | Air intake filter switch fault (earlier models) |
| 24 | Remote control buttons held too long, or operational switch fault |
| 29 | Condensate not draining (condensing models) or heat exchanger temperature too low |
| 31 | Inlet water temperature sensor (thermistor) fault |
| 32 | Heat exchanger thermistor fault |
| 33 | Outlet (outgoing water) thermistor fault |
| 34 | Ambient or combustion air temperature sensor fault |
| 35 | Improper thermistor connection |
| 51 | Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier) |
| 52 | Modulating gas valve (PGFR) fault |
| 61 | Blower (combustion fan) motor fault |
| 65 | Water volume control valve fault |
| 66 | Water bypass valve fault |
| 71 | Gas inlet solenoid valve fault |
| 72 | Flame rod fault: flame sensed before ignition |
| 76 | Remote control communication fault |
| 79 | Blower (fan) motor current fault |
| 80 | Gas cut-off failure: flame detected after the unit turned off |
| 82 | Control board program chip fault (current) / gas type data failure (earlier) |
| 90 | Vent blockage detected before ignition |
| 92 | Neutralizer needs replacing soon (warning, condensing models) |
| 93 | Neutralizer must be replaced; unit will not operate (condensing models) |
| 1L | Lime (scale) buildup detected in the heat exchanger |
| 99 | Vent blockage detected after shutdown / blocked flue (hard lockout) |
| P1 | Not enough water flow to fire the burner (warning) |