Rheem 72

Rheem code 72: flame rod fault

Short answer

Code 72 is a flame sensing fault on Rheem tankless heaters. On current models, the flame rods detect flame before the igniter activates. Earlier models call it a flame sensing device fault and list checking that the rod touches the flame, removing debris, checking wiring and voltage, cleaning carbon off the rod and replacing it.

In this guide
  1. What it means by model generation
  2. What a technician checks
  3. What you can do
  4. How to reset it
  5. Before you call

Flame rods prove the burner is lit. If they sense flame when there should be none, or give a bad signal, the heater shuts down for safety.

This page uses two Rheem sources: the current Rheem and Ruud tankless troubleshooting manual, and Rheem's error code list for earlier tankless models. Codes can differ between generations, so the meaning for each is shown where they differ. Rheem technical support: (800) 432-8373.

What it means by model generation

Rheem generationMeaning
Current modelsFlame rods detecting flame before the igniter is activated
Earlier modelsFlame sensing device fault

If you smell gas, do not reset the unit or touch switches. Leave the building and call your gas utility from outside.

What a technician checks

  • Connectors to the flame rods and gas valve, reseated
  • Indoor models have two flame rods; outdoor models have one
  • Carbon buildup on the rod, cleaned or the rod replaced
  • Foreign material in the burner chamber
  • Wiring and flame rod voltage
  • The gas control valve, if flame persists when it should be off

What you can do

Reset once. If code 72 returns, call a technician. The flame rods sit in the sealed combustion area. See our tankless water heater flame sensor replacement guide for typical prices.

How to reset it

  1. Close all hot water taps.
  2. Turn the remote control off, wait about 10 seconds, then turn it back on.
  3. Open a hot tap and watch whether the code returns.

Before you call

Have the model and serial number from the rating label ready, and note whether your unit is a condensing (high-efficiency) or non-condensing model. Tell the technician the exact code, when it appears and any recent work on the gas, water, venting or electrical supply. That often saves a second visit.

See every code on our Rheem error codes page.

Common questions

Can a dirty flame rod cause Rheem code 72?

Earlier Rheem guidance lists cleaning carbon buildup off the rod. On current models the code specifically means flame was sensed too early.

Was this article helpful?

Other Rheem codes

CodeMeaning
00 Continuous combustion for more than one hour
03 Communication failure between units, remote or manifold controller
05 Improper combustion detected by the flame rod (warning)
10 Air supply or exhaust blockage (hard lockout)
11 Ignition failure
12 Flame failure
13 Poor combustion detected by the flame rod (indoor units)
14 Overheat safety tripped
15 Heat exchanger or hot water temperature too high (boiling safety)
16 Outlet water temperature above the set point (over temperature warning)
21 Air intake filter switch fault (earlier models)
24 Remote control buttons held too long, or operational switch fault
29 Condensate not draining (condensing models) or heat exchanger temperature too low
31 Inlet water temperature sensor (thermistor) fault
32 Heat exchanger thermistor fault
33 Outlet (outgoing water) thermistor fault
34 Ambient or combustion air temperature sensor fault
35 Improper thermistor connection
51 Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier)
52 Modulating gas valve (PGFR) fault
61 Blower (combustion fan) motor fault
65 Water volume control valve fault
66 Water bypass valve fault
71 Gas inlet solenoid valve fault
72 Flame rod fault: flame sensed before ignition
76 Remote control communication fault
79 Blower (fan) motor current fault
80 Gas cut-off failure: flame detected after the unit turned off
82 Control board program chip fault (current) / gas type data failure (earlier)
90 Vent blockage detected before ignition
92 Neutralizer needs replacing soon (warning, condensing models)
93 Neutralizer must be replaced; unit will not operate (condensing models)
1L Lime (scale) buildup detected in the heat exchanger
99 Vent blockage detected after shutdown / blocked flue (hard lockout)
P1 Not enough water flow to fire the burner (warning)

All Rheem error codes