Rheem 99

Rheem code 99: blocked flue or vent

Short answer

Code 99 means a venting blockage. On current Rheem and Ruud models, the unit detected a blockage during its post-purge cycle after shutting down, or was run before the vent was installed, and it is a hard lockout that needs the reset procedure. Earlier models call it a blocked flue fault and list cleaning the heat exchanger, combustion fan, inlet filter and exhaust flue.

In this guide
  1. What it means by model generation
  2. What to check
  3. What you can do
  4. Before you call

After the burner shuts off, the fan keeps running briefly to clear exhaust. If the heater senses a blockage during that post-purge, it locks out with code 99.

This page uses two Rheem sources: the current Rheem and Ruud tankless troubleshooting manual, and Rheem's error code list for earlier tankless models. Codes can differ between generations, so the meaning for each is shown where they differ. Rheem technical support: (800) 432-8373.

What it means by model generation

Rheem generationMeaning
Current modelsVent blockage detected during post-purge, after shutdown (hard lockout)
Earlier modelsBlocked flue fault

Rheem classifies this as a hard lockout code. The unit will not restart with a normal reset; a technician clears it with a reset procedure on the control board after fixing the cause.

What to check

  • Vent terminals: snow, ice, leaves, nests
  • Approved vent materials, terminations and lengths
  • Spacing between terminals, so exhaust is not drawn back in
  • Vent seals
  • On earlier models: blockage in the heat exchanger, combustion fan, inlet filter and exhaust flue

What you can do

Clear the vent terminals, then call a technician to perform the lockout reset and inspect the venting. See our tankless water heater venting requirements guide.

Before you call

Have the model and serial number from the rating label ready, and note whether your unit is a condensing (high-efficiency) or non-condensing model. Tell the technician the exact code, when it appears and any recent work on the gas, water, venting or electrical supply. That often saves a second visit.

See every code on our Rheem error codes page.

Common questions

What is the difference between Rheem code 90 and 99?

On current models, 90 is detected before ignition and 99 after shutdown. Both point to venting.

Was this article helpful?

Other Rheem codes

CodeMeaning
00 Continuous combustion for more than one hour
03 Communication failure between units, remote or manifold controller
05 Improper combustion detected by the flame rod (warning)
10 Air supply or exhaust blockage (hard lockout)
11 Ignition failure
12 Flame failure
13 Poor combustion detected by the flame rod (indoor units)
14 Overheat safety tripped
15 Heat exchanger or hot water temperature too high (boiling safety)
16 Outlet water temperature above the set point (over temperature warning)
21 Air intake filter switch fault (earlier models)
24 Remote control buttons held too long, or operational switch fault
29 Condensate not draining (condensing models) or heat exchanger temperature too low
31 Inlet water temperature sensor (thermistor) fault
32 Heat exchanger thermistor fault
33 Outlet (outgoing water) thermistor fault
34 Ambient or combustion air temperature sensor fault
35 Improper thermistor connection
51 Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier)
52 Modulating gas valve (PGFR) fault
61 Blower (combustion fan) motor fault
65 Water volume control valve fault
66 Water bypass valve fault
71 Gas inlet solenoid valve fault
72 Flame rod fault: flame sensed before ignition
76 Remote control communication fault
79 Blower (fan) motor current fault
80 Gas cut-off failure: flame detected after the unit turned off
82 Control board program chip fault (current) / gas type data failure (earlier)
90 Vent blockage detected before ignition
92 Neutralizer needs replacing soon (warning, condensing models)
93 Neutralizer must be replaced; unit will not operate (condensing models)
1L Lime (scale) buildup detected in the heat exchanger
99 Vent blockage detected after shutdown / blocked flue (hard lockout)
P1 Not enough water flow to fire the burner (warning)