Rheem 33
Rheem code 33: outlet water sensor fault
Short answer
Code 33 is an outlet thermistor fault on Rheem and Ruud tankless heaters: the sensor that measures the temperature of water leaving the unit. Current models call it an outlet thermistor malfunction, with a resistance range of about 7,000 to 23,000 ohms. Earlier models list checking the wiring, testing the sensor, cleaning scale off it and replacing it.
In this guide
The outlet thermistor tells the heater how hot the water leaving it is, so it can hold your set temperature. Code 33 means that reading is invalid.
This page uses two Rheem sources: the current Rheem and Ruud tankless troubleshooting manual, and Rheem's error code list for earlier tankless models. Codes can differ between generations, so the meaning for each is shown where they differ. Rheem technical support: (800) 432-8373.
What it means by model generation
| Rheem generation | Meaning |
|---|---|
| Current models | Outlet thermistor malfunction |
| Earlier models | Outgoing water temperature sensor fault |
What a technician checks
- Resistance at the control board connector, about 7,000 to 23,000 ohms per Rheem's manual
- The wiring from the sensor to the board
- Scale on the sensor, which earlier models' remedy says to clean off
A sensor that is out of range after cleaning is replaced.
Why it matters
Without a good outlet reading, water temperature can swing or the heater shuts down. Rheem lists the outlet thermistor first when diagnosing code 16 as well.
How to reset it
- Close all hot water taps.
- Turn the remote control off, wait about 10 seconds, then turn it back on.
- Open a hot tap and watch whether the code returns.
Before you call
Have the model and serial number from the rating label ready, and note whether your unit is a condensing (high-efficiency) or non-condensing model. Tell the technician the exact code, when it appears and any recent work on the gas, water, venting or electrical supply. That often saves a second visit.
See every code on our Rheem error codes page.
Common questions
Can hard water cause Rheem code 33?
Scale on the sensor can affect it. Earlier Rheem guidance includes cleaning scale off the sensor.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rheem codes
| Code | Meaning |
|---|---|
| 00 | Continuous combustion for more than one hour |
| 03 | Communication failure between units, remote or manifold controller |
| 05 | Improper combustion detected by the flame rod (warning) |
| 10 | Air supply or exhaust blockage (hard lockout) |
| 11 | Ignition failure |
| 12 | Flame failure |
| 13 | Poor combustion detected by the flame rod (indoor units) |
| 14 | Overheat safety tripped |
| 15 | Heat exchanger or hot water temperature too high (boiling safety) |
| 16 | Outlet water temperature above the set point (over temperature warning) |
| 21 | Air intake filter switch fault (earlier models) |
| 24 | Remote control buttons held too long, or operational switch fault |
| 29 | Condensate not draining (condensing models) or heat exchanger temperature too low |
| 31 | Inlet water temperature sensor (thermistor) fault |
| 32 | Heat exchanger thermistor fault |
| 33 | Outlet (outgoing water) thermistor fault |
| 34 | Ambient or combustion air temperature sensor fault |
| 35 | Improper thermistor connection |
| 51 | Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier) |
| 52 | Modulating gas valve (PGFR) fault |
| 61 | Blower (combustion fan) motor fault |
| 65 | Water volume control valve fault |
| 66 | Water bypass valve fault |
| 71 | Gas inlet solenoid valve fault |
| 72 | Flame rod fault: flame sensed before ignition |
| 76 | Remote control communication fault |
| 79 | Blower (fan) motor current fault |
| 80 | Gas cut-off failure: flame detected after the unit turned off |
| 82 | Control board program chip fault (current) / gas type data failure (earlier) |
| 90 | Vent blockage detected before ignition |
| 92 | Neutralizer needs replacing soon (warning, condensing models) |
| 93 | Neutralizer must be replaced; unit will not operate (condensing models) |
| 1L | Lime (scale) buildup detected in the heat exchanger |
| 99 | Vent blockage detected after shutdown / blocked flue (hard lockout) |
| P1 | Not enough water flow to fire the burner (warning) |