Rheem tankless code 12: flame failure, causes and fixes
Short answer
Code 12 means the Rheem lit the burner but lost the flame during operation. The usual causes are gas pressure that drops when other appliances run, venting problems, or a dirty or loose flame rod.
Where code 11 means the burner never lit, code 12 means it lit and then went out. The unit shuts off the gas and displays the code.
Code 12 is often intermittent. Pay attention to when it happens, because the timing points to the cause.
What to check first
- Does code 12 appear when the furnace, dryer or range is also running? That points to gas supply.
- Check the vent terminal outside, especially on windy days or after snow.
- Confirm the gas valve to the heater is fully open and, on propane, that the tank has gas.
- Reset the unit at the controller and run hot water.
Common causes
Gas pressure drops under load
If the gas line is undersized, pressure can sag when several appliances fire at once. The flame becomes unstable and goes out.
Venting and wind
A partly blocked vent or a terminal exposed to strong wind can disturb the flame.
Flame rod
Carbon or buildup on the flame rod can make the unit lose the flame signal even when the flame is burning. Cleaning or replacing it is a technician job.
When to call a technician
If code 12 keeps returning, a technician should measure gas pressure with everything running and service the flame rod.
Common questions
Why does my Rheem show code 12 only sometimes?
Intermittent code 12 often lines up with other gas appliances running or with windy weather. Note when it happens and tell your technician.
Was this article helpful?
Sorry about that. What was missing?
Please do not include personal information. Links are not accepted.
Thanks for your feedback. It helps us improve our guides.
Other Rheem codes
| Code | Meaning |
|---|---|
| 00 | Continuous combustion for more than one hour |
| 03 | Communication failure between units, remote or manifold controller |
| 05 | Improper combustion detected by the flame rod (warning) |
| 10 | Air supply or exhaust blockage (hard lockout) |
| 11 | Ignition failure |
| 12 | Flame failure |
| 13 | Poor combustion detected by the flame rod (indoor units) |
| 14 | Overheat safety tripped |
| 15 | Heat exchanger or hot water temperature too high (boiling safety) |
| 16 | Outlet water temperature above the set point (over temperature warning) |
| 21 | Air intake filter switch fault (earlier models) |
| 24 | Remote control buttons held too long, or operational switch fault |
| 29 | Condensate not draining (condensing models) or heat exchanger temperature too low |
| 31 | Inlet water temperature sensor (thermistor) fault |
| 32 | Heat exchanger thermistor fault |
| 33 | Outlet (outgoing water) thermistor fault |
| 34 | Ambient or combustion air temperature sensor fault |
| 35 | Improper thermistor connection |
| 51 | Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier) |
| 52 | Modulating gas valve (PGFR) fault |
| 61 | Blower (combustion fan) motor fault |
| 65 | Water volume control valve fault |
| 66 | Water bypass valve fault |
| 71 | Gas inlet solenoid valve fault |
| 72 | Flame rod fault: flame sensed before ignition |
| 76 | Remote control communication fault |
| 79 | Blower (fan) motor current fault |
| 80 | Gas cut-off failure: flame detected after the unit turned off |
| 82 | Control board program chip fault (current) / gas type data failure (earlier) |
| 90 | Vent blockage detected before ignition |
| 92 | Neutralizer needs replacing soon (warning, condensing models) |
| 93 | Neutralizer must be replaced; unit will not operate (condensing models) |
| 1L | Lime (scale) buildup detected in the heat exchanger |
| 99 | Vent blockage detected after shutdown / blocked flue (hard lockout) |
| P1 | Not enough water flow to fire the burner (warning) |