Rheem tankless code 12: flame failure, causes and fixes

Short answer

Code 12 means the Rheem lit the burner but lost the flame during operation. The usual causes are gas pressure that drops when other appliances run, venting problems, or a dirty or loose flame rod.

In this guide
  1. What to check first
  2. Common causes
  3. When to call a technician

Where code 11 means the burner never lit, code 12 means it lit and then went out. The unit shuts off the gas and displays the code.

Code 12 is often intermittent. Pay attention to when it happens, because the timing points to the cause.

What to check first

  1. Does code 12 appear when the furnace, dryer or range is also running? That points to gas supply.
  2. Check the vent terminal outside, especially on windy days or after snow.
  3. Confirm the gas valve to the heater is fully open and, on propane, that the tank has gas.
  4. Reset the unit at the controller and run hot water.

Common causes

Gas pressure drops under load

If the gas line is undersized, pressure can sag when several appliances fire at once. The flame becomes unstable and goes out.

Venting and wind

A partly blocked vent or a terminal exposed to strong wind can disturb the flame.

Flame rod

Carbon or buildup on the flame rod can make the unit lose the flame signal even when the flame is burning. Cleaning or replacing it is a technician job.

When to call a technician

If code 12 keeps returning, a technician should measure gas pressure with everything running and service the flame rod.

Common questions

Why does my Rheem show code 12 only sometimes?

Intermittent code 12 often lines up with other gas appliances running or with windy weather. Note when it happens and tell your technician.

Was this article helpful?

Other Rheem codes

CodeMeaning
00 Continuous combustion for more than one hour
03 Communication failure between units, remote or manifold controller
05 Improper combustion detected by the flame rod (warning)
10 Air supply or exhaust blockage (hard lockout)
11 Ignition failure
12 Flame failure
13 Poor combustion detected by the flame rod (indoor units)
14 Overheat safety tripped
15 Heat exchanger or hot water temperature too high (boiling safety)
16 Outlet water temperature above the set point (over temperature warning)
21 Air intake filter switch fault (earlier models)
24 Remote control buttons held too long, or operational switch fault
29 Condensate not draining (condensing models) or heat exchanger temperature too low
31 Inlet water temperature sensor (thermistor) fault
32 Heat exchanger thermistor fault
33 Outlet (outgoing water) thermistor fault
34 Ambient or combustion air temperature sensor fault
35 Improper thermistor connection
51 Gas valve fault: flame detected after shutdown (current) / gas inlet solenoid valve fault (earlier)
52 Modulating gas valve (PGFR) fault
61 Blower (combustion fan) motor fault
65 Water volume control valve fault
66 Water bypass valve fault
71 Gas inlet solenoid valve fault
72 Flame rod fault: flame sensed before ignition
76 Remote control communication fault
79 Blower (fan) motor current fault
80 Gas cut-off failure: flame detected after the unit turned off
82 Control board program chip fault (current) / gas type data failure (earlier)
90 Vent blockage detected before ignition
92 Neutralizer needs replacing soon (warning, condensing models)
93 Neutralizer must be replaced; unit will not operate (condensing models)
1L Lime (scale) buildup detected in the heat exchanger
99 Vent blockage detected after shutdown / blocked flue (hard lockout)
P1 Not enough water flow to fire the burner (warning)